Improving curing quality with multiple wind direction by resolving lack of airflow in clean oven
Guaranteeing cleanness of Class 100 by applying HEPA filter (99.97%; 0.3㎛)
Automatic alarming of filter exchange cycle by applying digital differential pressure gauge
Automatically operable with VGA linked by applying Auto Door
Door opening allowed at blackout
Excellent temperature control competence for ensuring the best temperature uniformity
PC-based control program for easy to use
Exclusive software for convenient system operation and data management
Good structure for sealing and heat insulation
Protecting specimens with overloading preventing system
Definition of Class 100?
Environment of high cleanness with number of particles of 0.5 ㎛ size kept at 100 or lower per cubic foot.
Cleanness of common indoor space is about Class 500,000.
Model | VSCO-2CM | |
---|---|---|
Control | Temp. Control | UP-55A(30 Pattern, 99Segment) |
Main. Control | IPC | |
Temperature | Range | Amb.+10℃ ~ 250℃ |
Uniformity | ±3% | |
Ramp up time | Room Temp ~ 175℃ Within 30 min | |
Cooling down time | 175℃ - 80℃ Within 30 min | |
Sensor type | K-CA | |
Cleanliness | Main Filter | HEPA Filter (99.97% 0.3㎛) |
Air Cleanliness | Fad. Standard 209E Class100, ISO 14644-1 Class5 | |
AirFlow Type | Horizontal | |
Cooling type | Water Cooling | 2~5kg/cm2 |
Purge | N2 Gas | 0 ~ 200 SCFH |
Dry Air | 0 ~ 200 SCFH | |
Material | Internal | Stainless Steel |
External | Stainless Steel 1.2t or Steel 1.2t power coating | |
Heater | 12kw / Chamber | |
Insulation | Mineral wool | |
Door gasket | Anti ESD Silicone Rubber | |
Safety device | Electronic Control over temp. limit 1ea, Mechanical over temp. limit 1ea |
|
Size (W×D×H) | Internal(㎜) | 660×750×800 |
External(㎜) | 1540×1500×1970 | |
Electric requirement | 220VAC, 3 Phase 50Hz/60Hz |
-Automatic Door: Automatic operation allowed by making use of AGV
-Clean oven: Class100 (High temperature HEPA filter applied, 99.97%; 0.3 ㎛)
-Automatic display of filter exchange cycle
-Temperature uniformity ensured by multi-airflow design: Uniformity ±3%
-Precision of temperature control: ±0.1℃
-Saving cycle time by applying chamber loading mode for individual operation
-Implementing digital recording functions and networking
-Temperature adjustment and multiple step curing functions via control panel
-Saving data in LAN network and CIM, and PC hard disk
-Automatic display of input/output time on LCD monitor